DR300 Resource Library

Dokument-ID

Dokument-ID PR358

Veröffentlichungsdatum

Veröffentlichungsdatum 25.05.2022
Titel
DR300 Resource Library
Produkt Überblick
This is the Resource Library to house all DR300 Supporting Documentation.
Kundeninformation

The DR300 Pocket Colorimeter

 
Additional Procedures and Manuals are available on Hach.com. Use the 'Kit #' link to visit the product page for additional downloads.
 
Parameter Range Kit # Manual Procedure
Chlorine, F/T 0.02-2.00 mg/L Cl2
0.1-8.0 mg/L Cl2
LPV445.97.00110 User Manual: DR300_DOC022.97.90639 
User Manual: DR300_DOC022.L3.90639
User Manual: DR300_DOC022.L1.90639
User Manual: DR300_DOC022.L2.90639
DR300 Service Manual_DOC222.53.90639
Chlorine, Free and Total, Low Range, DPD Method 8021 (free)/8167 (total), AccuVac Ampuls, DR300 and Pocket Colorimeter II_DOC316.53.01450
Chlorine, Free and Total, High Range, DPD Method, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01449
Chlorine, F/T 0.05-4.00 mg/L Cl2
0.1-10.0 mg/L Cl2
LPV445.97.62110 User Manual: DR300_DOC022.97.90639  Chlorine, Free and Total, Mid-Range, DPD Method 10245 (free)/10250 (total), Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01451
Chlorine, Free and Total, High Range, DPD Method 10069 (free)/10070 (total), Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01490
Chlorine, pH 0.1-10.0 mg/L Cl2
6.0-8.5 pH
LPV445.97.12110 User Manual: DR300_DOC022.97.90639  Chlorine, Free and Total, High Range, DPD Method 10069 (free)/10070 (total), Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01490
pH, Phenol Red Method 10076, RS, DR300 and Pocket Colorimeter II_DOC316.53.01491
Monochlor/Free Ammonia 0.05-4.50 mg/L Monochloramine as CL2
0.02-0.50 Free Ammonia as NH3-N
LPV445.97.26110 User Manual: DR300_DOC022.97.90639  Chloramine (Mono) and Nitrogen, Free Ammonia, Indophenol Method 10200, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01445
Phosphate 0.02-3.00 mg/L PO4 LPV445.97.06110 User Manual: DR300_DOC022.97.90639  Phosphorus, Reactive (Orthophosphate), PhosVer® 3 Method 8048, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II_DOC316.53.01471
Phosphonates, PhosVer® 3 with Persulfate UV Oxidation Method 8007, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01470
Ozone 0.01-0.25 mg/L O3
0.01-0.75 mg/L O3
LPV445.97.04110 User Manual: DR300_DOC022.97.90639  Phosphorus, Reactive (Orthophosphate), PhosVer® 3 Method 8048, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II_DOC316.53.01471
Phosphonates, PhosVer® 3 with Persulfate UV Oxidation Method 8007, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01470
Iron 0.02-5.00 mg/L Fe LPV445.97.22110 User Manual: DR300_DOC022.97.90639  Phosphorus, Reactive (Orthophosphate), PhosVer® 3 Method 8048, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II_DOC316.53.01471
Iron 0.01-1.70 mg/L Fe LPV445.97.16110 User Manual: DR300_DOC022.97.90639  Iron, Total TPTZ Method 8112, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01457
Chlorine Dioxide 0.05-5.00 mg/L ClO2 LPV445.97.51110 User Manual: DR300_DOC022.97.90639  Chlorine Dioxide, DPD Method 10126, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01447
Molybdenum 0.02-3.00 mg/L Mo
0.1-12.0 mg/L Mo
LPV445.97.10110 User Manual: DR300_DOC022.97.90639  Molybdenum, Low Range, Ternary Complex Method 8169, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01463
Molybdenum, High Range, Ternary Complex Method 8169, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01462
Nitrate 0.4-30.0 mg/L NO3-N LPV445.97.02110 User Manual: DR300_DOC022.97.90639  Nitrate, HR Cadmium Reduction Method 8039, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II_DOC316.53.01465
Ammonia 0.01-0.80 mg/L NH3-N LPV445.97.40110 User Manual: DR300_DOC022.97.90639  Nitrogen, Ammonia-Salicylate Method 8155 Powder Pillows, DR300 andPocket Colorimeter II_DOC316.53.01466
Bromine 0.05-4.50 mg/L Br
0.2-10.0 mg/L Br
LPV445.97.01110 User Manual: DR300_DOC022.97.90639  Bromine, Low Range, DPD Method 8016, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II_DOC316.53.01444
Bromine, High Range, DPD Method 8016, Powder Pillows or AccuVac® Ampuls, DR300 and Pocket Colorimeter II_DOC316.53.01443
Zinc 0.02-3.00 mg/L Zn LPV445.97.09110 User Manual: DR300_DOC022.97.90639  Zinc, Zincon Method 8009, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01476
Manganese 0.2-20.0 mg/L Mn LPV445.97.15110 User Manual: DR300_DOC022.97.90639  Manganese, Periodate Oxidation Method 8034, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01460
Oxygen, Dissolved 0.2-10.0 mg/L O2 LPV445.97.03110 User Manual: DR300_DOC022.97.90639  Dissolved Oxygen, HRDO Method 8166, HR AccuVac® Ampuls, DR300 and Pocket Colorimeter II_DOC316.53.01467
Aluminum 0.02-0.80 mg/L Al LPV445.97.25110 User Manual: DR300_DOC022.97.90639  Aluminum, Aluminon Methos 8012, Powder Pillows, DR300 and Pocket Colorimeter II_DOC316.53.01441
Single Wavelength, 528 nm Custom LPV445.97.52110 User Manual: DR300_DOC022.97.90639  NA
Single Wavelength, 500 nm Custom LPV445.97.50110 User Manual: DR300_DOC022.97.90639  NA
Single Wavelength, 600 nm Custom LPV445.97.60110 User Manual: DR300_DOC022.97.90639  NA
Single Wavelength, 655 nm Custom LPV445.97.65110 User Manual: DR300_DOC022.97.90639  NA
 

More Information:

 
Application Notes, FAQ's and More


 Application Note: High Range Cyanuric Acid Analysis_DOC042.53.20277

User Manual: DR300_DOC022.97.90639

 User Instruction: DR300 Communication Dongle_DOC272.99.90639

Certificate of Analysis Technical Data for Validation Free Chlorine Powder Pillows (0.02 – 2.00 mg/L)_COA Free Chlorine PP- English-2105569

Certificate of Analysis Technical Data for Validation Total Chlorine Powder Pillows (0.02 – 2.00 mg/L)_COA Total Chlorine PP-English-2105669