PIB 37-647 PAH500 Product Launch

Dokument-ID

Dokument-ID PIB523

Veröffentlichungsdatum

Veröffentlichungsdatum 09.05.2022
Titel
PIB 37-647 PAH500 Product Launch
Zusammenfassung
Product Launch for distribution to Global subscribers.
Applies to the Hach Process brands.

Introduction:

Hach is pleased to announce the launch of the PAH500 sensor, a sensor dedicated to measuring polycyclic aromatic hydrocarbons (PAH) in maritime exhaust gas cleaning system (scrubber) applications.

Key Message Points
  • Built for maritime: purpose built for harsh maritime applications, the sensor utilizes a titanium housing and quartz measurement tube for longevity in seawater.
  • Minimal maintenance: the unique flow-through design means there are no pumps, tubes, or valves that can foul, resulting in minimal maintenance and maximum uptime.
  • Reliability: hundreds of successful installations on inlet/outlet scrubber applications speak to the reliability of the PAH500.
Level One - Customers-Distributors-Internal
Product Information:
PAH500 Part Numbers
Product # Description Other Information
LXV541.99.1001H PAH500 Digital PAH Sensor, 1.0 m Cable, Bracket Includes sensor, gateway, extension cable, mounting hardware, cleaning swabs
LXV541.99.2001H PAH500 Digital PAH Sensor, 7.7 m Cable, Bracket Includes sensor, gateway, extension cable, mounting hardware, cleaning swabs
LXV541.99.3001H PAH500 Digital PAH Sensor, 15.0 m Cable, Bracket Includes sensor, gateway, extension cable, mounting hardware, cleaning swabs
LXV541.99.4001H PAH500 Digital PAH Sensor, 31.0 m Cable, Bracket Includes sensor, gateway, extension cable, mounting hardware, cleaning swabs
 
PAH500 Accessory Numbers
Product # Description Other Information
6122400 Digital Extension Cable, 1 m (3.3 ft.)  
5796000 Digital Extension Cable, 7.7 m (25 ft.)  
5796100 Digital Extension Cable, 15 m (50 ft.)  
5796200 Digital Extension Cable, 31 m (100 ft.)  
6166300 Drain Valve  
6845000 ¼" NPT Plug  
LXZ541.99.0001H Mounting Brackets  
 
PAH500 Reagent and Consumable Part Numbers
Product # Description Other Information
LZC541 PAH500 Sensor Calibration Kit Includes 25 and 50 ppb standards, deionized water, valve, plug, cleaning swabs, and transfer pipettes
2563899 Phenanthrene Standard, 25 ppb Includes standard in ampule, transfer vial, and ampule breaker
2563901 Phenanthrene Standard, 50 ppb Includes standard in ampule, transfer vial, and ampule breaker
2088000 Alconox Detergent For cleaning
2088153 Liqui-Nox Detergent For cleaning
1227642 Isopropyl Alcohol For cleaning
244932 Sulfuric Acid, 5.25 N For cleaning
9774000 Cleaning Swab, pk/50 For cleaning
2749320 Disposable Pipettes, pk/20 For cleaning/calibration